Introduction of Environmental Tests
Environmental test is a method for testing quality of raw materials, semi-finished products and
finished products by simulating various environmental climates for verifying if materials and
products reach the quality objectives expected in R&D, designing, and manufacturing by
various environmental testing equipments. It is widely used in different fields, such as aviation,
aerospace, military, shipbuilding, electrical industry, electronics, medical industry, photovoltaic
industry, lighting industry, petrochemical, and automobile, etc. The main applications of
environmental tests in enterprises are in research test, stereotype test, production inspection test,
product acceptance test, safety test and reliability test.
Environmental Main Test Items and Applicable Standards
Environmental Test Equipment
Constant temperature and humidity chamber
Quantity: 50pcs;
Volume: 225L, 408L, 1000L, 4m³, 8m³
Temperature range: -70~+200℃
Humidity range: 10~95%
Rate of heating and cooling: heating rate: about 3℃/min; cooling rate: about 1℃/min
Test projects: high temperature, low temperature, high and low temperature cycle, damp heating test, constant humidity and heating test
8m³ Walk-in temperature and humidity chamber
Temperature range: -40~+150℃
Humidity range: 20~95%
Rate of heating and cooling:heating rate about +3℃/min;cooling rate: about +1℃/min
Thermal shock chamber(two-box with lifting cage)
Quantity: 6
Volume: 80L, 150L, 270L
Temperature range: -55~+150℃
Temperature conversion time: ≤5 sec
2m³ Two-box thermal shock chamber (left-right sliding basket)
Temperature range: -55~+180℃
Volume: 2m³
Temperature conversion time: ≤5sec
Three-box Thermal Shock Chamber
Quantity: 3
Volume: 80L, 400L
Temperature range: -40~+150℃
Temperature conversion time: ≤3sec
Rapid temperature change chamber(ESS Rapid temperature change chamber (ESS stress screening) is mainly used stress screening)
Quantity: 6
Volume: 225L, 408L, 1m³
Temperature range: -50~+150℃
Rate of temperature change (linear) :
225L(≤10℃/min)
1m³ (≤25℃/min)
High and low temperature low pressure test chamber
Chamber dimension:1000*1000*1000mm
Temperature range: -50~+150℃
Pressure range: 常压~0.5Kpa
Voltage dropping time: ≤45min(normal pressure~1Kpa)
Ultraviolet photoaging chamber
Temperature range: -10~+70℃
Humidity range: 50~95%
Chamber dimension: 1140x500x500mm
Irradiance range: ≤1.0W/m2
Lamp type: UVA340/UVB313/UVA351
Solar Radiation
Temperature range: 10~70℃
Humidity range: 50~95%
Chamber volumn: 512L
Irradiance range: (wavelength 280~800nm): 0-
1200±15% W/m2;
Irradiance range (wavelength 340nm): 0-0.7 W/m2
Irradiance range (wavelength 420nm): 0-1.1 W/m2
Environmental reliability test chiller for chilling components (new energy vehicle motor controller, battery management system)
Temperature range: -40 ℃~+120 ℃
Low temperature chiller: -40 ℃~+40℃
High temperature chiller: +40℃~+120 ℃
Chilling power: 20KW
Max. velocity: 6m³/H
Temperature fluctuation: ±1℃
Testing Lab | Certifications | News | About DDT | Service | Contact us |
Business Consulting: 0769-3882-6677 Headquarters Tel: 0769-3882-6678 Fax: 0769-3882-6679 E-mail: service@dgddt.com Company address: Building B, No. 17, General Headquarters 2nd Road,Songshan Lake National High-tech Industrial Development Zone, Dongguan City,Guangdong Province, China Tianjin Dongdian Testing Service Co., Ltd Tel:022-58038033 Tianjin Address:Building D, No. 19, Wei 4th Road,Microelectronics Industrial Zone,Tianjin Development Zone. Copyright © 2018-2019 ddttest.com Dongguan Dongdian Testing Service Co., Ltd. All rights reserved.Testing and Certification Company Certification Body 粤ICP备17000636号-2 |